Product Details:
Payment & Shipping Terms:
|
Power: | 220V 50/60 Hz | Usage: | Corrosion Resistant Testing |
---|---|---|---|
Color: | Light Grey | Uses: | Composite Salt Spray Test Chamber |
Temp. Air: | NSS.ACSS 47°C±1°C/CASS 63℃±1℃ | Standards: | GB/T2423.17,ASTM B117,CNS3627 |
Highlight: | salt spray corrosion test chamber,salt mist chamber |
Copper Accelerated Acetic Acid Salt Spray (CASS) test machine with high performance
The Copper Accelerated Acetic Acid Salt Spray (CASS) test, often referred to as the Salt Fogging Test, is used to simulate and evaluate the corrosive performance of decorative copper/nickel/chromium or nickel/chromium coatings on steel, zinc or aluminium alloys and plastics designed for severe service.
Salt Spray Test Chambers offer the most realistic and dependable corrosion test, widely used to test corrosion resistance of automotive, paint, surface coating, chemical, aerospace, electronic, car industry, offshore and defense industries.
The types of coatings that can be assessed through the copper accelerated acetic acid salt spray test include:
This test is widely employed in industrial settings. It is very beneficial for replicated service evaluation, development and research as well as manufacturing control. Specifically, it is developed for electrode posited, decorative chromium/nickel as well as chromium/nickel/copper.
Features:
1, Chamber material is made of P.P Sheet, sturdily and will not be out of shape.
2, Test chamber is heated from five directions to ensure the temperature is uniformity distributed.
3, Spray nozzle is specially made, enable to spray the salt water with considerable speed, then falls on the surface of samples.
4, Hot and moist air keeps the humidity in the test chamber conforms testing request.
5, High precision P.I.D. temperature controller limits the temperature difference within the range of ±0.1℃.
Specifications:
Please Note Small Type of 60 and 90 do not meet standard of ASTM B117.
Model | AHL-60-SS | AHL-90-SS | AHL-120-NS | AHL-160-NS | AHL-200-NS | ||
Model (Touch Screen) | AHL-60-TS | AHL-90-TS | AHL-120-TS | AHL-160-TS | AHL-200-TS | ||
Interior dimensions (mm) |
W | 600 | 900 | 1200 | 1600 | 2000 | |
D | 450 | 600 | 850 | 1000 | 1200 | ||
H | 400 | 500 | 500 | 550 | 600 | ||
Exterior dimensions (mm) |
W | 1130 | 1460 | 2200 | 2600 | 3000 | |
D | 630 | 910 | 1200 | 1450 | 1650 | ||
H | 1070 | 1280 | 1450 | 1550 | 1600 | ||
Chamber Volume | 108 L | 270 L | 480 L | 800 L | 1440 L | ||
Solution Tank | 15L | 25 L | 40L | ||||
Power Supply | AC 220V 50HZ | AC 380V 50HZ | |||||
Ambient temp. & | +5℃ ~ +35℃ / <85%RH | ||||||
Testing Temperature | NSS ACSS 35℃±1℃ / CASS 50℃±1℃ | ||||||
Air Temperature | NSS ACSS 47℃±1℃ /CASS 63℃±1℃ | ||||||
Solution Consistence | NaCl 5% | ||||||
PH Value | NASS ACSS:6.5~7.2 / CASS:3.0~3.2 | ||||||
Temperature fluctuation | ≦±0.5℃ | ||||||
Temperature uniformity | ≦2. 0℃ | ||||||
Temperature deviation | ≦±2.0℃ | ||||||
Spray quantum | 1.0~2.0(ml/80cm2/h) | ||||||
Chamber Material | polyvinyl chloride (PP) | ||||||
Heater | Corrosion‐resistant titanium tube | ||||||
Temperature sensor | Platinum Resistance (PT‐100) | ||||||
Safety device | Over‐temperature protection, leakage protection |
Optional accessories:
1. Control Panel : Key panel / LCD panel (optional)
2. Working way: steam heating type / air heating type (optional)
3. Salt concentration meter
4. Air compressor
Contact Person: Mr. Andy DAI
Tel: +86-13450058229
Fax: 86-769-2278-4276