Product Details:
Payment & Shipping Terms:
|
Volume: | Internal 100L, 40 X 50X 50cm | Temperature: | Range -40℃ ~ +150℃ |
---|---|---|---|
Fluctuation: | Humidity ±1.5% | Power Supply: | AC220V, 50Hz/60Hz |
Color: | White, Purple, Red | Heating Rate: | 3 Degree C / Min |
Humidity: | Range 20% -98% R.H | Refrigerant: | R23/R507 |
Highlight: | temperature controlled chamber,climatic test chamber |
Cold Balanced Control System Simulation Environment Alternate Temperature
Humidity Test Chamber for Quality Control
Temperature humidity chamber can simulate different environment condition. It's appropriate for testing material performance, such as resist heat, resist dry, resist humidity and resist cold. That can define performance of material. It is simple to operate and program easy to edit. It can show the set values and operative time.
Cooling Method of Climate Test Chamber: Air cooled or water cooled?
This might be an easy decision: With water cooled condensers, the chamber requires a dedicated conditioned waterline. All chambers can be air or water cooled however water cooled units will lower the temperature in the chamber workspace faster than an air cooled chamber.
Condenser Comparison | Air Cooled | Water Cooled |
Heat rejection | Positive heat rejection | Little to no heat rejection |
Energy efficiency | Less efficient | More efficient |
Footprint | Larger space requirement | Smaller space requirement |
Pull-down times | Slower rate | Faster rate |
Purchase price | Less costly for small units | Less costly for large units |
Installation | Easy | Must supply conditioned water cooling loops |
Features:
1, Chamber exterior material is stainless steel with environmentally baking paint resists corrosion and provides impact resistance. Interior material is SUS304# stainless steel ,mirror finished with excellent heat resistance and easy to clean.
2, Controller imported LCD display screen can be displayed measuring values and setting the value and time.
3, Safety relay connection is provided to protect your device under test by removing power to it when the chamber is not running.
4, RS-232 communications is for computer connection, programming can be set on computer by software, monitor testing process and automatically execute power on/off functions.
5, Fog-free viewing window and interior light makes viewing workspace freely and observe the test under best conditions.
6, Adjustable product shelf slides out for easier product access. Shelf design is non-tipping and supports large product loads.
7, Left and right side of chamber with diameter 100mm cable port for power-on test.
8, Optional electronic humidity sensor is used on all test chambers for accuracy and minimal maintenance.
9,The French Tecumseh brand is used for the circulation system of the compressor, more effective removal of oil between the condenser and the capillary and use environmentally refrigerants ( R23, R404, R507).
10.Completely independent system separate for testing in high temperature, low temperature and constant temperature&humidity environment
11.Water supply system that is externally connectable, convenient for refilling water into the humidifying tank and automatically recyclable chamber
Test standards:
GB/T2423.1-2001 test A: Low temperature (part)
GB/T2423.2-2001 test B: High temperature (part)
GB/T2423.3-2006 test Cab : Steady damp-heat
GB/T2423.4-1993 test Db: Alternating humid heat
GB/T2423.34-2005 test Z/AD: Temperature and humidity combination
GB/T2423.3,4 requirements for the heat and humid heat cycle of the medium steady state
GB/T5170.2-2008 electric and electronic products environmental testing equipment method temperature test equipment
GB/T5170.5-2008 electric and electronic products environmental testing equipment method hygrothermal test equipment.
IEC68-2-1 (GB-2423.1-2008) Testing A: Low temperature testing method
IEC68-2-2 (GB-2423.2-2008) Testing B: High temperature testing method
IEC68-2-3 (GB2423.3-93) Testing Ca: Constant moist heat testing method.
MIL-STD-202F (GJB360.8-87) High temperature life testing
MIL-STD-810D (GJB150.9-93) Moist heat testing method
Technical Specification:
The test conditions for device performance parameters are: cooling cycle is 25 ºC, no-load (no load) |
||||||
Category | model | QTH-100C/D | QTH-200C/D | QTH-330C/D | QTH-600C/D | QTH-1000C/D |
Internal size(W*H*D) mm |
500×500 ×400 |
580×750 ×450 |
580×750 ×760 |
800×950 ×800 |
1100×950 ×950 |
|
External size(W*H*D) mm |
750×1650 ×1100 |
880×730 ×1360 |
880×1730 ×1570 |
1100×1950 ×1700 |
1400×2000 ×2105 |
|
Main performance | Temperature range | C:-40C~+150C, D:-70C~+150C customize | ||||
Temperature fluctuation | ±0.5ºC | |||||
Temperature uniformity | ±2.0ºC (deviation:±2.0ºC) | |||||
Humidity range | 20%~98%(Dry sphere temperature range+10ºC~+90ºC) | |||||
Humidity fluctuation | ±1.5% | |||||
Humidity uniformity | <75% RH /≤±5%RH; >75% RH /≤±3%RH | |||||
Heating performance | Average about 3 degrees per minute, no load. | |||||
Cooling performance | C:from +20ºC to -40ºC , average about 1 degrees per minute, no load | |||||
D:from +20ºC to -70ºC , average about 1 degrees per minute, no load | ||||||
Operating ambient temperature |
Environmental temperature conditions for equipment functioning normally:+5ºC~35ºC |
|||||
Structure | Outer box material | Steel plate lacquer-full computer white | ||||
Inner box material | SUS304(or316) mirror stainless steel | |||||
Insulation process | Outer rigid polyurethane foaming+Inner glass fiber cotton | |||||
System | Refrigeration mode | C: Mechanical vapor compression refrigeration-Single stage; cooling mode optional: Air cooling (standard) / water cooling. | ||||
D: Mechanical vapor compression refrigeration-Overlapping type; Cooling mode optional air cooling (standard) / water cooling |
||||||
Refrigeration compressor |
Fully enclosed piston type/rotary compressor (Low noise / environmental protection) |
|||||
Cryogen |
C: Environmental coolant R404A D: Environmental coolant R404A+R23 |
|||||
Circulating fan | High-temperature induction motor+aluminum alloy centrifugal wind blade | |||||
Heater | Reliable stainless steel regenerator | |||||
Humidifier |
Built-in stainless steel anti-corrosive heating pipe,Water plate humidification (Convenient and clean, low water consumption) |
|||||
Control system | Control method | Solidified write PLC control system | ||||
Display screen |
7-inch TFT true color liquid crystal display with a resolution of 800*480; hand touch input |
|||||
Operation mode | Values and programs | |||||
Program capacity | 120 group programs, each program can be set up 100 times | |||||
Document storage |
USB interface,Easy to import or export internal parameters of programs and devices ; curve data can be derived from USB disk |
|||||
Communication |
Optional LAN Network Interface, it is convenient for remote connection control and fault diagnosis. |
|||||
Water supply | Water supply mode | Pump lift | ||||
Water box | 5-liter / 20-liter food-grade PE tank, removable for cleaning | |||||
Water quality requirements | Resistance for water used for humidification≥500mΩ | |||||
Parts | Standard configuration |
Diameter 100mm test hole and soft plug 2 piece; stainless steel riser with good air permeability 2 piece; movable casters with fixed mats 4 piece,observation window 1 piece |
||||
Protection | Standard configuration |
Power over-voltage overload protection;Power leakage protection switch; test product over temperature protection (independent); compressor overload high - voltage protection; heater over-temperature protection; humidifier dry burning protection; low water level protection ; Controller self-diagnosis fault picture display. |
||||
Others | Power Supply |
100L uniphase220V; others 3 phase 4 line380V 50Hz ±10%+protective earth wire |
||||
Single-phase maximum current A | 18A | 18A | 18A | 22A | 26A | |
Power rating KW | 4KW | 7KW | 7KW | 10KW | 10KW | |
Nominal weight KG | 180 | 280 | 320 | 500 | 700 |
Contact Person: Mr. Andy DAI
Tel: +86-13450058229