Product Details:
Payment & Shipping Terms:
|
Internal Volume: | 80L, 40 X 50 X 40cm | Temperature: | Range 0℃ ~ +150℃ |
---|---|---|---|
Humidity: | 20% ~ 90%RH | Control Mode: | Balanced Temp & Humidity Control System |
Fluctuation: | ±0.5deg; ±2.5%RH | Heating Rate: | 0℃ ~ +100℃ Within 30min |
Highlight: | temperature controlled chamber,climatic test chamber |
Touch Screen Programmable Constant Temperature and Humidity
Test Chamber in purple color
Features:
1, Chamber exterior material is stainless steel with environmentally baking paint resists corrosion and provides impact resistance. Interior material is SUS304# stainless steel with excellent heat resistance and easy to clean.
2, Touch screen controller is designed to save chamber programming and setup time with temperature limit and alarm to protect your product.
3, Safety relay connection is provided to protect your device under test by removing power to it when the chamber is not running.
4, RS-232 communications is for computer connection, programming can be set on computer by software, monitor testing process and automatically execute power on/off functions.
5, Fog-free viewing window and interior light makes viewing workspace freely and observe the test under best conditions.
6, Adjustable product shelf slides out for easier product access. Shelf design is non-tipping and supports large product loads.
7, Left side of chamber with diameter 50mm (support customized) cable port for power-on test.
8, Optional electronic humidity sensor is used on all test chambers for accuracy and minimal maintenance.
Conform but not limited below international testing standards:
IEC68-2-1 (GB-2423.1-2008) Testing A: Low temperature testing method
IEC68-2-2 (GB-2423.2-2008) Testing B: High temperature testing method
MIL-STD-202F (GJB360.8-87) High temperature life testing
MIL-STD-810D (GBJ150.3) High temperature method
MIL-STD810D (GBJ150.4) Low temperature method
IEC68-2-3 (GB2423.3-93) Testing Ca: Constant moist heat testing method.
IEC68-2-30 (GB2423.4-93) Testing Db: Alternate moist heat testing method.
MIL-STD-810D (GJB150.9-93) Moist heat testing method
Optional Accessories:
Cable Port: Size of cable port is available for 100mm
Water purifier RO 80: Continuously provide purified water for humidifying heater and wet-bulb
Dehumidifier: The rotation regenerating dehumidifier M-120 ensures precise control of low humidity (10C, 15%RH) for electrostatic reliability tests.
Defrosting Device: The chamber automatically detects and melts the frost on the evaporator when operating below 0deg in order to allow continuous operation
Electronic humidity sensor: Precision Humidity Sensor with stainless steel protection tube.
Technical Specifications:
Control Mode | Balanced Temperature and Humidity Control System |
Operating Temp. & Humid. Range | +5deg ~ +35deg; <85%R.H. |
Temp. range | A=0deg, B=-20deg, C=-40deg, D=-70deg ~ +100deg(150deg) |
Humid. range | 20% ~98%R.H. (Optional: 5%~98%R.H.) |
Temp. & Humid. fluctuation | ±0.5deg; ±2.5%R.H. |
Temp. & Humid. uniformity | ≤2.0deg; ≤3%R.H. |
Temp. & Humid. Deviation | ≤1.0deg; ≤2%R.H. |
Temp. Heating Time | 0deg ~ +100degwithin 30min; -20deg ~ +150degwithin 45min |
Temp. Cooling Time | 20deg ~ -40degwithin 60min; 20deg ~ -70degwithin 85min |
Power Supply | AC380V, 50/60HZ, Three-phase (Specified by User) |
Exterior Material | stainless steel with baking paint |
Interior material | SUS304# Stainless steel |
Insulation material | Rigid Polyurethane foam |
Refrigeration system | Mechanical cascade refrigeration system; Fin type radiator |
Circulation system | Mechanical convection system |
Humidification Water Supply |
Automatic water regulating, recoverable supply system, water shortage alarm system |
Water quality | Distilled water only, 20L Water tank capacity |
Controller | Touch Screen Controller |
Safety devices | Overheat protector Switch, Compressor overload protector Switch water shortage protector Switch, Humidifier protector Switch Fault alarm system |
Model Selection:
Model | Temp and Humidity Range | Internal Dimension (W x H x D) cm |
Exterior Dimension (W x H x D) cm |
QTH-V80A |
0℃~﹢150℃ 20%~98%RH |
40x50x40 | 65x120x130 |
QTH-V150A | 50x60x50 | 75x130x155 | |
QTH-V225A | 50x75x60 | 75x145x155 | |
QTH-V416A | 70x85x70 | 95x185x165 | |
QTH-V800A | 100x100x80 | 125x195x175 | |
QTH-V1000A | 100x100x100 | 125x195x185 | |
QTH-V80B |
-20℃~﹢150℃ 20%~98%RH |
40x50x40 | 65x120x130 |
QTH-V150B | 50x60x50 | 75x130x155 | |
QTH-V225B | 50x75x60 | 75x145x155 | |
QTH-V416B | 70x85x70 | 95x185x165 | |
QTH-V800B | 100x100x80 | 125x195x175 | |
QTH-V1000B | 100x100x100 | 125x195x185 | |
QTH-V80C |
-40℃~﹢150℃ 20%~98%RH |
40x50x40 | 65x120x130 |
QTH-V150C | 50x60x50 | 75x130x155 | |
QTH-V225C | 50x75x60 | 75x145x155 | |
QTH-V416C | 70x85x70 | 95x185x165 | |
QTH-V800C | 100x100x80 | 125x195x175 | |
QTH-V1000C | 100x100x100 | 125x195x185 | |
QTH-V80D |
-70℃~﹢150℃ 20%~98%RH |
40x50x40 | 65x120x130 |
QTH-V150D | 50x60x50 | 75x130x155 | |
QTH-V225D | 50x75x60 | 75x145x155 | |
QTH-V416D | 70x85x70 | 95x185x165 | |
QTH-V800D | 100x100x80 | 125x195x175 | |
QTH-V1000D | 100x100x100 | 125x195x185 | |
Remark: 20%~98%RH is standard humidity range, support custom made 10%~98%RH Or 5%~98%RH | |||
Support custom made dimension |
Contact Person: Mr. Andy DAI
Tel: +86-13450058229
Fax: 86-769-2278-4276